C. Connect the WH-1002 wire harness branch coming from the relay to the factory power source re-
moved in the Step 1b.
B. Disconnect power source to the factory lift pump.
D. Secure Relay in an upright position, as shown, to prevent moisture from entering. Di-electric grease
may be applied to prevent corrosion. Examples of locations to secure relay:
A. Using ring terminals, attach red wire of the WH-1002 to the positive
battery terminal. Attach green wire to a clean ground, preferably the
negative battery terminal. Secure fuse block in a location protected from
outside elements. The use of corrosion preventative spray is recom-
mended.
E. Route the WH-1002 wire harness along the frame rail to the mounting location of the FASS fuel
pump.
The installation of the electrical harness is done first, allowing power to be applied to the pump for
lubrication purposes later in the installation.